Diethylhexylphthalate DEHP is a phthalate a chemical substance that is frequently used to soften PVC Polyvinyl Chloride medical devices such as blood bags tubing catheters and disposable gloves to make materials more pliable and comfortable to use. The increasing knowledge of the effects of phthalate exposure which can be teratogenic carcinogenic or induce reproductive toxicity has
People of Baxter Delivering Care in More Ways Than One Baxter service specialist Pedro Perez routinely delivers life saving and sustaining peritoneal dialysis PD solutions and supplies into the homes of patients. One day late in 2020 he was called upon
Baxter Healthcare CorporationPaclitaxel Set Non Vented Spike Polyethylene Lined Tubing Interlink Injection Site 0.2 Micron Filter Male Luer Lock Adapter 10 drops/ml 108 Length Pump segment and fluid path does not contain DEHP outer layer of polyethylene lined tubing does contain DEHP 48/cs Rx Continental US Only Excluding IN ND and WY Product Access Restricted.
Description The INTERLINK universal vial adapter is non DEHp and non PVC. CS CS 20 mEq/L Potassium Chloride in 5 Dextrose and 0.9 Sodium Chloride Injection USP Grade.
The Clearlink System Non DEHP Continu Flo Solution Set 2R8519 2R8537 2R8546 consists of a spike tip protector non vented spike non DEHP drip chamber non DEHP tubing check valve slide clamp regulating roller clamp Clearlink Luer activated valve LAV two
Non DEHP PVC tubing material that uses Di 2 Ethylhexyl terephthalate as a plasticizer conversion to sterile packaging and the addition of an expiration date. The proposed Non DEHP PVC tubing material is currently used in Baxter’s Solution Sets with 1.2 Micron Air Eliminating Filter and has been previously cleared under 510 k premarket
Solution Set with DUO VENT spike. Manufacturer Baxter Healthcare. For use with rigid non vented and flexible containers. Compatible with FLO GARD 6201 and FLO GARD 6301 Series Pumps. DEHP and non DEHP options available. Sterile fluid path. Specifications. Connection Type. Luer Lock.
DEHP Free. Our IV sets are DEHP free. Infusion Therapy Standards of Practice advise to usee administration sets free of di ethylhexyl phthalate DEHP to administer lipid based infusates such as IVFE or TNA. DEHP is lipophilic and is extracted into the lipid solution with commonly used polyvinyl chloride administration sets and containers.
10125 mL/hr with IV tubing use of not greater than 36 hours 126250 mL/hr with IV tubing use of not greater than 4 hours 10.3 The Baxter non DEHP administration sets should not be used with the SIGMA Spectrum Pump for medications and
Description of the Baxter Healthcare Non DEHP Extension Set with 0.22 Micron Filter . Extension Set with 0.22 Micron High Pressure Extended Life Filter Male Luer Lock Adapter with Retractable Collar Non DEHP Approximate Volume 3.9 mL Approximate Length 9 23 cm . Filter has passed bacterial and pyrogen retention testing for 96 hours.
Oct 10 2020 Empty INTRAVIA Container 500 mL. Sterile nonpyrogenic fluid path. Port Tubes which contact fluid path are Non DEHP PVC. Blue port protector which does not contact fluid path contains DEHP plasticized PVC.
addition non PVC bags and tubing are typically used to administer TPN further lessening the concern about DEHP mediated effects. The dose of DEHP received by neonates undergoing TPN
Feb 01 2016 Baxter/Baxa Repeater Compatible Pump Set. ACTAPPS001. Single lead pharmacy fluid transfer tubing set with universal spike silicone pump insert male luer. Materials NON DEHP PVC SILICONE ABS. Fluid pathway sterile in an unopened package. Latex free pyrogen free. For use with peristaltic pumps. Available in various configurations multiple
Straight Type Catheter Extension Set Microbore ONE LINK Needle free IV Connector with Neutral Fluid Displacement Power Injectable 325 psi/2241 kPa . Approximate Volume 0.30 mL. Approximate Length 8.5 21.6 cm . Non DEHP. Sterile Package Nonpyrogenic. Show More
Solution Set Clearlink 10 Drops mL Drip Rate 76 Inch Tubing 1 Port SOLUTION SET N/DEHP 10DPM 76 48/CS
Prepare teniposide in a NON DEHP container. Recommend using the NON DEHP IV tubing with the build in 0.22 micron in line filter during administration. 1 2 3 12 Thiotepa 0.22 micron filter May undergo polymerization forming insoluble polymeric derivatives. 1 2 3 Thymoglobulin 0.22 micron in line filter 2 TPN Without lipids
CONTINU FLO Solution Set Non Vented 2 CLEARLINK Luer Activated Valves Backcheck Valve. 10 drops/mL. 96 2.4 m . Non DEHP. CONTINU FLO Solution Set with Non Vented Spike 2 CLEARLINK Luer Activated Valves Backcheck Valve and Male Luer Lock Adapter with retractable collar.
Baxter IV Extension Sets 1/Pkg BAXTER CENTER FOR SERVICE. Patterson Item # . Manufacturer Item # ACT5612 See My Price. Specifications Non DEHP Tubing N Material Dry natural rubber DEHP Luer Fitting
Paclitaxel Set Non Vented Spike with Polyethylene Lined Tubing and CLEARLINK Luer Activated Valve 0.2 Micron Filter Male Luer Lock Adapter. Approximately 10 drops/mL. Approximate Length 107 2.7 m . Non DEHP Pump Segment. Sterile Fluid Path. Fluid path does not contain DEHP Outer layer of polyethylene lined tubing contains DEHP. Show More
Plasticizers are organic compounds added to polymers to increase the flexibility and toughness of the finished product. Di 2 ethylhexyl phthalate DEHP is a plasticizer in the phthalate family that is commonly added to polyvinyl chloride PVC as a softener. Many industrial and consumer products contain phthalates and humans can potentially be exposed to high amounts of the chemical. 1
Mar 08 2018 Excellent Working Condition. Baxter Generic Sets/Tubing. 50 each case Flogard/Spectrum Compatible. Dimensions9 x11 x13 . Approx. Weight 5. We are a Distributor and have access to as many cases as needed. 10 drops/mL. Non DEHP Fluid Path. Priming Volume 13 mL approx. Length 100 .
Solution Set Clearlink 10 Drops mL Drip Rate 76 Inch Tubing 1 Port SOLUTION SET N/DEHP 10DPM 76 48/CS
Jul 22 2019 Like many other medicines in Baxter s portfolio of premix and ready to use injectables Myxredlin uses Baxter s proprietary Galaxy container technology. Galaxy is a non PVC and non DEHP system that enables premixed medicines to have a longer shelf life when stored at room temperature. Premixed and ready to use formats of standard doses of
Description of the Baxter Healthcare Non DEHP Extension Set with 0.22 Micron Filter . Extension Set with 0.22 Micron High Pressure Extended Life Filter Male Luer Lock Adapter with Retractable Collar Non DEHP Approximate Volume 3.9 mL Approximate Length 9 23 cm . Filter has passed bacterial and pyrogen retention testing for 96 hours.
BAXTER SECONDARY ADMINISTRATION SET 2C7461. Baxter Healthcare CorporationSecondary Medication Set Hanger Male Luer Lock Adapter 10 drops/ml 37 Length Non Pyrogenic Contains DEHP Sterile Fluid Path 48/cs Rx Continental US Only Excluding IN ND and WY Product Access Restricted. Check with your sales rep to verify eligibility
Dec 15 2020 To meet the preferences of some customers and address drug compatibility issues in specific clinical applications Baxter offers a portfolio of intravenous medications parenteral nutrition solutions injectable drugs biopharmaceuticals IV sets and access devices and other products that use or are contained in non PVC materials or non DEHP
IV Tubing Extension Set Baxter InterLink Catheter From 3.25. Buy Now. INTERLINK System Non DEHP standard bore catheter extension set with 1 injection site and male Luer lock adapter. Categories ALS IV Supplies IV Catheters IV Supplies.
CLEARLINK. Paclitaxel Set Polyethylene Lined Tubing Non DEHP Pump Segment 0.2 Micron Filter Luer Activated Valve Male Luer Lock Adapter. Company Name BAXTER INTERNATIONAL INC. Version or Model 2C8858. Commercial Distribution Status In Commercial Distribution. Device IDs Package Primary
Non DEHP Tubing Compare. 118 2C6750HEA. Item # 118 2C6750HEA. Blood/Solution Set Y Type 10 Drops/mL Interlink Injection Site. By BAXTER HEALTHCARE DMG. Your Price Log in List Price 23.29 EA. Log in for availability. View Product Details. More info Close info. Product Features Y type blood/solution set with standard blood filter 170μ
Areas of Use of DEHP DEHP is not known to occur naturally. The worldwide production of DEHP has been increasing over the past several decades. Around 97 of DEHP is used as a plasticizer in polymers mainly PVC. Exposure to DEHP varies widely and is dependent on Medical procedure Lipophilicity or ability of a chemical compound to dissolve in lipids of the fluid that comes into contact
Dec 15 2020 Myxredlin is stored in Baxter s proprietary Galaxy IV bag. Flexible container is non PVC non DEHP and not made with natural rubber latex No adsorption of insulin to the container Preservative free On Demand Availability. 30 day room temperature storage so it can be stored closer to the point of care
Non DEHP Microbore Catheter Extension Set Needle free IV Connector with Neutral Fluid Displacement Power Injectable Male Luer Lock Adapter Company Name BAXTER INTERNATIONAL INC. Version or Model 7N8310
Feb 01 2016 Baxter/Baxa Repeater Compatible Pump Set. ACTAPPS001. Single lead pharmacy fluid transfer tubing set with universal spike silicone pump insert male luer. Materials NON DEHP PVC SILICONE ABS. Fluid pathway sterile in an unopened package. Latex free pyrogen free. For use with peristaltic pumps. Available in various configurations multiple
Mar 29 2021 DEHP A softener for polyvinyl chloride PVC a plastic polymer used in a wide array of products. Unplasticized PVC is hard and brittle at room temperature. A plasticizer softener is typically added to increase the flexibility of the polymer. DEHP is the plasticizer for most PVC medical devices. Devices that may contain DEHP plasticized
Description Choose from sterile nonpyrogenic fluid path containers with PVC ports or containers with non DEHP di ethylhexyl phthalate fluid path. CS CS CS CS CS CS
Nov 19 2004 e Baxter Solution Set 76 1.9 m Volume 3.7 mL Non DEHP Tubing Cassette with AutoClamp Device Male Luer Lock Adapter product code 2M9860 f Baxter Solution Set 112 7.9 m Volume 3.7 mL Non DEHP Tubing Cassette with AutoClamp Device 1.2 Micron Downstream Filter Male Luer Lock Adapter product code 2M9861